Jet Filter Type NJF / Duo
The NEUERO JET filter "Type NJF" is a newly developed blower with integrated filter for the ventilation of grinding and mixing plants.
Gallery
‹
›
Jet Filter Type NJF / NJF Duo
The NEUERO JET filter "Type NJF" is a newly developed blower with integrated filter for the ventilation of grinding and mixing plants. Its main purpose is the prevention of condensation, which improves the quality of the mixed material and increases operational safety.
Construction Advantages
- Location-independent installation: The filter can be flexibly integrated into existing plants.
- Compact design: Space-saving and ideal for tight installation situations.
- Easy maintenance: Filter replacement is straightforward and quick to perform.
Efficient Filter Cleaning
The cleaning of the filter elements is carried out electropneumatically by short compressed air pulses. This ensures constant filter performance and extends the service life of the filters.
JET Filter Duo – Enhanced Performance
The Duo variant offers:
- Double filter area: Significantly reduces the filter area load.
- Longer maintenance intervals: Less downtime and reduced maintenance effort.
- Higher air performance: Optimal for larger grinding and mixing plants.
Flexible Control
The JET filter can be:
- Operated independently of the plant control.
- Integrated into the existing control system – for automated and optimized process management.
Versatile Applications
In addition to ventilating mixing plants, the JET filter is also suitable for:
- Dust removal from grain conveying systems
- Extraction at screening machines
Technical Data
Jet Filter Type NJF / Duo |
||
|---|---|---|
| Type | Typ NJF | Typ NJF Duo |
| Number of Filters [pcs.] | 1 | 2 |
| Filter Length [mm] | 1500 | 1500 |
| Filter Diameter [mm] | 200 | 200 |
| Air Flow Rate [m³/h] | 550 – 1.350 | 1.200 – 2.300 |
| Compressed Air Requirement approx. [bar] | 5 – 8 | 5 – 8 |
| Air Volume Uncompressed approx. [l/h] | 150 | 150 |
| Cleaning Interval | every 3 minutes | every 3 minutes |
| Cleaning Duration | 0,5 seconds | 0,5 seconds |
| Noise Emission | quiet | quiet |
| Control | independent or integrated | independent or integrated |
| Optional Accessories | Stand elevation | Stand elevation |
×